WM22-DIN: three-phase power
analyzer
Harmonic analysis; Energy meters;
Plug and play technique. These
are only a few among many other
functions performed by your
WM22-DIN. What’s more,
Carlo Gavazzi means ISO9001
certification, a working experience
of many decades and a wide-
spread presence all over the world.
All this because we want our
customers to have the top service
and the top products.
Welcome in the Carlo Gavazzi
world and compliments for your
smart choice. Visit our website at:
www.carlogavazzi.com
T
h
a
n
k
y
o
u
f
o
r
c
h
o
o
s
i
n
g
C
a
r
l
o
G
a
v
a
z
z
i
CARLO GAVAZZI
Automation Components
EN61036
EN61268
Przeglądanie stron 0
1 2 3 4 5 6 ... 39 40

Podsumowanie treści

Strona 1 - CARLO GAVAZZI

WM22-DIN: three-phase poweranalyzerHarmonic analysis; Energy meters;Plug and play technique. Theseare only a few among many otherfunctions performed b

Strona 2 - FW rev. 02

▲▲10 VT ratioThis function allows the user to se-lect the value of the VT ratio. Exam-ple: if the primary of the connectedVT (voltage transformer) is

Strona 3 - Displayed pages

▲▲11 Total Harmonic DistortionThis function allows the user to en-able the FFT analysis and the dis-play of the total harmonic distortion(see also “

Strona 4 - To begin with

▲▲12 Digital Outputs❑ Digital Output 1This function enables to set the pa-rameters of the open collector dig-ital outputs. Choose the “diGout”functio

Strona 5

▲▲13❑ Alarm Digital OutputThis function allows the user to setthe parameters of the alarm digitaloutput. Choose the “diGout1- ALr ”function by means o

Strona 6

▲▲14❑ Digital output 2ACt EnE: enables the retransmissionof the active energy by means ofpulses; confirm with and after-wards set the number of puls

Strona 7

▲▲15 RS422/ 485 Serial port addressSelect “AddrESS” from the mainmenu by means of the and keys; to enter the menu press ,then set the desired a

Strona 8

▲▲16 Reset of Total metersSelect “rESEt tot” from the mainmenu by means of the and keys, confirm with : when theinstrument asks for the reset

Strona 9

▲▲17 Only in the 5(10)A versionReset of the maximum valuesof the dmd powersSelect “rESEt dmd” from the mainmenu by means of the and keys, confirm

Strona 10 - Programming

▲▲18 Only in the version 20(90)A.Reset of the maximum currentvaluesSelect “rESEt m” from the mainmenu by means of the and keys, confirm it with

Strona 11

▲▲19Useful informationReset of the meters1723List of the variables23The variables measured by the instrument arecorrect if the polarities of the input

Strona 12

▲▲2Index3Front panel4CARLO GAVAZZIWM22 DIN, three-phase power analyzer.FW rev. 02TO BEGIN WITH...

Strona 13

▲▲20 CT and VT programming; Open collector PulseDigital Output TableThe CT is programmable from 1 to 5000, the VT is program-mable from 1.0 to 199.9

Strona 14

▲▲21Useful informationExample 11919Module combination2523are reset (after an alert message for confirmation). The reso-lution of the energy meters is

Strona 15

▲▲22 Alarm digital outputThe activation of the alarm can be high or low depending on how theON and OFF parameters have been set, as per the following

Strona 16

▲▲23IT IS IMPORTANT that the instrument is switchedoff when you plug-in or disconnect the modules.For SAFETY reasons, in the 20 (90)A version,the tig

Strona 17

▲▲24Installation How to remove the front coverPressTo remove the front cover of WM22, press contemporane-ously the four release levers at the fo

Strona 18

▲▲25InstallationNOITPIRCSEDELUDOM-FLESDEILPPUSREWOPYRAILIXUAYLPPUSA A Btuptuorotcellocnepo0092OA)etomerromrala,eslup(✓✓tuptuoeugolana1292OA/0292OA✓tup

Strona 19 - Useful information

▲▲26 Removing the modulesIdentificationlabelConnectionlabelSlot for thescrewdriverTo remove the modules, use a screwdriver. Insert the scre

Strona 20

▲▲27 Dimensions and panel cut-outHoledistancesdimensionsfor panelmountingDimensionsforpanel-cut-out 1 2 1 2 on onSlot BAccess toprogramming:ALLOWED

Strona 21

▲▲28Installation Open collector output connections245A Electrical connections29List of the variables2333 Analogue output connections RS422/ 485 Ser

Strona 22

▲▲294-wire connectionFig.2: Direct connectionwithout neutral (3-wiresystem).Unbalanced load.Auxiliary power supplyFig.1: Direct connectionwith neutral

Strona 23

▲▲3Go to the page where the previous mainsubject is described.Go to the page where the next main subject isdescribed.Go to the page where the subject

Strona 24 - Installation

▲▲30 5 A Version Electrical DiagramsFig.4: Direct connectionwith/without neutral(3-wire system).Unbalanced load.Auxiliary power supplyLOADFig.3: dire

Strona 25

▲▲31Installation90A connections292433Technical features35Fig.7: 3-phase ARONCT connection withoutneutral. Unbalancedload.Auxiliary power supply 5 A v

Strona 26

▲▲32Fig. 8: ARON CT andVT connection withoutneutral (3-wire system).Unbalanced load.Auxiliary power supplyFig.9: CT and VTconnection with neutral(3-wi

Strona 27

▲▲33InstallationDual-phase system3124Software functions38Fig.10: CT and VTconnection withoutneutral (3-wire system).Unbalanced load.Fig.11: CT and V

Strona 28

▲▲34 Number of inputsCurrent: 3Voltage: 4 AccuracyDisplay, RS422/485 Ib: 5A, Imax: 10A; Ib: 20A, Imax: 90A.Current: from 0.003Ib to 0.2Ib: ±(0.5%RDG

Strona 29

▲▲35Technical featuresHF electromagnetic fields: < 1%Influence of accessories: 0 Temperature drift≤ 200ppm/°C Sampling1000 samples/s at 50Hz Dis

Strona 30

▲▲36 Rated input voltages (Un)/rangeAV0-AV4: 208VL-L / -20% ≤ Un ≤ + 20%AV8: 208VL-L / -20% ≤ Un ≤ + 15%AV1-AV5-AV9: 400VL-L / -20% ≤ Un ≤ + 15%AV3-A

Strona 31

▲▲37Technical featuresMeasurements3534 40Scaling factor: programmable within the whole retransmissionrange; it allows the retransmission of all the va

Strona 32

▲▲38Technical features5A connections3334 40- one alarm output and one pulse output (kWh or kvarh)- one output remotely controlled by means of the seri

Strona 33

▲▲39System selection: three-phase with neutral, three-phase with-out neutral.Transformer ratio: CT from 1 to 5000; VT from 1.0 to 199.9and from 200 to

Strona 34 - Technical features

▲▲4To begin with Front panel descriptionDisplayprevious pageDisplaynext pageAccess toprogramming orSetting confirmationBacklightedLCD displayInstrume

Strona 35

▲▲40 General featuresOperating temperature: 0 to +55°C (R.H. < 90% non con-densing at 40°C).Storage temperature: -20 to +60°C (R.H. < 90% non

Strona 36

▲▲5Total harmonic distortionexpressed as % for thefollowing currents:A-L3A-L1A-L2Total kWhenergy meter.Total kvarhenergy meter.Partial kWhenergy meter

Strona 37

▲▲6WΣ is always 00 incase of connectionswithout neutral.W-L3W-L2W-L1VΣ is always 00 incase of connectionswithout neutralV-L3V-L2V-L1Err: it’s display

Strona 38

▲▲7VAΣ is always 00 incase of connectionswithout neutral.VA-L3VA-L2VA-L1VArΣ is always 00 incase of connectionswithout neutral.VAr-L3VAr-L2VAr-L1PFΣ

Strona 39

▲▲8 Access to the main menuTo access to the programmingmenus from the measuring and dis-play phase, press the key: whenthe instrument asks for the

Strona 40

▲▲9Programming1.2.. ..2.1Displayed pages7818Alarm output13 SystemThis function allows the operator toselect the electrical system choos-ing between t