UDM 35/40 Digital Panel Meter
Programming Guide
Przeglądanie stron 0
1 2 3 4 5 6 ... 21 22

Podsumowanie treści

Strona 1 - CARLO GAVAZZI

CARLO GAVAZZI Automation Components UDM 35/40 Digital Panel Meter Programming Guide

Strona 2

UDM 35/40 PANEL METER USER MANUAL 9Decimal Point Position (dP) The decimal point position is relative to the Display Value, which will be discus

Strona 3

UDM 35/40 PANEL METER USER MANUAL 10 Linearization Introduction When is displayed, a signal from a non-linear transducer-sensor may be modi

Strona 4

UDM 35/40 PANEL METER USER MANUAL 11 Navigating & Programming within the Linearization Menu As appears, press followed by and keys t

Strona 5

UDM 35/40 PANEL METER USER MANUAL 12 Hysteresis selection Off-Delay Value (0-255s) On-Delay Value (0-255s) Relay Selection (normall

Strona 6

UDM 35/40 PANEL METER USER MANUAL 13Navigating through this program sequence Minimum Set-Point The lowest value, below which, it is not possib

Strona 7

UDM 35/40 PANEL METER USER MANUAL 14Hysteresis The point at which an active alarm output must revert to for the alarm output to turn off. Exam

Strona 8

UDM 35/40 PANEL METER USER MANUAL 15 Configuring the Display Color for Alarm Event (UDM40/BD40 only) When is displayed, the color of the disp

Strona 9

UDM 35/40 PANEL METER USER MANUAL 16The second filter parameter is . It represents the filtering coefficient. The higher the value of Fil.C, th

Strona 10

UDM 35/40 PANEL METER USER MANUAL 17Programming example: Retransmit a 4-20mA signal proportional to the following displayed values: Lo.D = 0 and

Strona 11

CONVERTING CELSIUS TO FAHRENHEIT The UDM35/40 digital panel meters use the Celsius temperature scale. However, the displayed value can easily be sc

Strona 12

UDM 35/40 PANEL METER USER MANUAL 1 Index Description 2 Programming Fundamentals 3 Access to Programming Mode/Password Pr

Strona 13

UDM 35/40 PANEL METER USER MANUAL 18 External Command Function When is displayed, the user may elect to dedicate a Command signal (contact clo

Strona 14

UDMsoft Programming The software is menu driven. Just fill-in-the-blanks with your parameters. There is little explanation required. It is actually

Strona 15

UDM 35/40 PANEL METER USER MANUAL 19 Links: Resources & Data Sheets UDM 35 Datasheet https://www.gavazzionline.com/images/UDM35DS

Strona 16

UDM 35/40 PANEL METER USER MANUAL 2 UDM Description The UDM 35/40 series is a universal Digital Panel Meter that has been developed to

Strona 17

UDM 35/40 PANEL METER USER MANUAL 3 UDM 35/40 Programming Fundamentals There are no jumpers to consider when programming the UDM 35/40.

Strona 18

UDM 35/40 PANEL METER USER MANUAL 4 Access to Programming Mode Press and hold for 2 seconds. Display will indicate (password). With

Strona 19

UDM 35/40 PANEL METER USER MANUAL 5 Programming the Input Modules Press and hold for 2 seconds. Display will indicate PASS (password). With

Strona 20

UDM 35/40 PANEL METER USER MANUAL 6LSX and HSX input modules offer True RMS (trnS) or DC measurement (dC). Use keys to make selection. Pres

Strona 21

UDM 35/40 PANEL METER USER MANUAL 7 Press key to select Auto (Auto). Press to confirm. . Press to advance to next program step sequence.

Strona 22

UDM 35/40 PANEL METER USER MANUAL 8Scaling the Inputs When is displayed, access is available for configuring the electrical input range, t