2 Specifications are subject to change without notice (06.06.02)
Dupline
®
is a registered trademark. A product of the CARLO GAVAZZI Group
G 3800 0015, G 3800 1015
Real-time clock
Accuracy
Better than ± 1 minute/month
Internal back-up time Typ. 48 hours
Power ON delay < 2.5 s
Indication for
Supply ON LED, green
ON Line LED, yellow
COM 1 LED, red
COM 2 LED, red
RS 485 LED, red
GSM LED, red
Environment
Degree of protection IP 20
Pollution degree 3 (IEC 60664)
Operating temperature 0° to +50°C (+32° to +122°F)
Storage temperature -20° to +85°C (-4° to +185°F)
Humidity (non-condensing) 20 to 80% RH
Mechanical resistance
Shock 15 G (11 ms)
Vibration 2 G (6 to 55 Hz)
Dimensions
Material
(see "Technical Information") H8-housing
Weight 640 g
General Specifications
Wiring Diagram
RS 485
21
19210311412513614715816
2922 3023 3124 3225 3326 3427 3528 36
G 3800 0015 230
DUPLINE
115V
PNNP
115V
12 VA
+
D
D
0,1 A
30 V
1
234
(A) (B) V- V+
V-
V+
V+
1234
1
234
IN
V-
6-30 VDC
Supply
Inputs Outputs
Out
Pin Assignment, COM1, COM2 RS 232 Cable
2
3
5
2
3
5
9-pin male
to controller
9-pin female
to PC
5
9
1
6
Pin Signal
2 T x D
3 R x D
5 Signal Ground
Supply Specifications
Power supply AC-Types
Overvoltage cat. III (IEC 60664)
Rated operational voltage
through term. 21 & 24
jumper term. 22 & 23 230 VAC ± 15% (IEC 60038)
through term. 21 & 23
jumper term. 24 & 22 115 VAC ± 15% (IEC 60038)
Frequency 45 to 65 Hz
Rated operational power Typ. 7 VA/3 W
Rated impulse withstand
voltage 230 V 4 kV
115 V 2.5 kV
Dielectric voltage
Supply - Dupline
®
≥ 4 kVAC (rms)
Supply - Output ≥ 4 kVAC (rms)
Supply - Input ≥ 4 kVAC (rms)
Supply - Com. ports ≥ 4 kVAC (rms)
Heat dissipation 4 W