Conventional Energy
CARLO GAVAZZI Automation Components. Specifi cations are subject to change without notice. Illustrations are for example only.
12
DPA51
• Dimensions 81x17,5x67,2mm DINrail
housing
• Phase sequence and loss relay
• 3 phase AC (own power supply);
regenerated voltage
• Power supply from 208 to 480 VAC
• CE, UL, CSA and CCC approved
MAIN FEATURES
• Compressor protection from reverse
running and phase loss
• 17.5 mm width: the smallest in the
market
• Plug and play: no settings needed
Monitoring Relay
Our product range
DPA53
• Dimensions 81x17,5x67,2mm DIN-
rail housing
• Phase sequence, loss and undervoltage relay
• 3 phase AC (own power supply)
• Power supply from 208 to 480 VAC (2
models)
• UL, CSA and CCC approved
MAIN FEATURES
• Motor protection from reverse running
and wrong phase voltage
• 17.5 mm width: the smallest in the
market
• Plug and play: only undervoltage
threshold to be set
Monitoring relay
CPT
• Dimensions 83.5x45x98.5mm DINrail
housing
• Accuracy 0.5 % (voltage, current)
• Measurement by CT and VT
• Front protection degree IP20
• Analogue, digital, pulse or serial outputs
available
MAIN FEATURES
• Very compact size power transducer
• Provides electrical variables set to a PLC
to manage compressors and other loads
• Suitable for on-board panel installation
Power
transducers
DPB51
• Dimensions 81x17,5x67,2mm DIN-
rail housing
• TRMS 3-phase over/under voltage,
phase sequence and loss relay
• 3 phase AC (own power supply)
• Power supply from 208 to 480 VAC
• UL and CSA approved
MAIN FEATURES
• Detects the phase-phase or phase-neutral
voltage
• 17.5 mm width: the smallest in the
market
• Independent voltage setpoints and built-in
delays
Monitoring relay
DPC02
• Dimensions: 45 x 80 x 99.5 mm
• DIN rail mounting
• Power: 208 to 240 VAC or 380 to 415
VAC
• Protection degree: IP20
• Output: programmable relays 2 SPDT
N.E. or 1 DPDT N.E.
MAIN FEATURES
• One-phase and three-phase relays for
monitoring maximum and minimum
voltage and frequency, phase sequence
and phase failure. It checks that
frequency and voltage are within the
limits set by the energy supplier
Interface protections
DPC72
• Dimensions: 90 x 71 x 65 mm, 4-DIN mod.
• DIN rail mounting – sealable housing
• Values and intervention time programming
• Serial port RS485 Modbus RTU
• Protection degree: IP50
• Output: 1 DPDT N.E.
MAIN FEATURES
• One-phase and three-phase relays for
monitoring maximum and minimum
voltage and frequency, phase sequence
and phase failure. It checks that
frequency and voltage are within the
limits set by the energy supplier
• Record of the last 10 events (date, time
and reason for the event)
Interface protections
CTD / TADK
• CTD: currents from 40 to 4000 A
TADK2: 1-250 A
• Removable panel fi xing clips
• DIN-rail and panel mounting facility (TAD...)
• Double screw terminals (CTD)
• Sealable covers
• Case: ABS, self-extinguishing level UL 94 V-O
• Precision class: 0.5
MAIN FEATURES
• Wound primary / solid core or split-core
• Compliance with IEC 60185, VDE
0414-1 regulations
• Removable DIN-rail mounting holder
Current transformers
MI/MP
• Current transformers for monitoring
relays
• 1-phase (MI) or 3-phase (MP)
• 0.4 to 4 Vp output
• 5 to 500 A primary ranges available
MAIN FEATURES
• Compact CT for CG current, power,
power factor monitoring relay
• Output proportional to the highest of
the 3 currents (MP)
• Extended frequency range (40 Hz to
1 kHz)
Current transformers
Komentarze do niniejszej Instrukcji